Contour

Contour

CONTOUR
Cement-lime plaster
for preparing and aligning surfaces
 
  • For hand and machine application
  • For rooms with high humidity
  • Prevents mold
  • Excellent adhesion to porous concrete
    • Plastic and easy to use
    • High adhesion
    • For indoor and outdoor use
  • Waterproof
  • Freeze proof
  • 2 to 20 mm
  • Energy efficient

Quality Certificate:
CE
EN 998-1:2010
EN 998-1-GP-CSIII-W0

Dry building mix ТМ MASTER CV.1.SHT2 DSTU B V.2.7-126: 2011

Bar-code: 4820086380850
25 kg +/-1%

 

Modified dry building mix ТМ MASTER. CONTOUR designed to prepare and align concrete, brick and other mineral bases for further application of various decorative materials inside and outside buildings (thickness in one application - no more than 20 mm). Efficient for rooms with high humidity: kitchens, bathrooms, parking lots, cellars, basements and more. Suitable for hand and machine application (using plaster stations).

 

SURFACE PREPARATION

Surface preparation must be done in accordance with the State Building Standard of Ukraine DBN V.2.6-22-2001. The base must be:

- clean (remove dirt, flows, dust, fungal lesions with a power tool or manually, also clean from residual oils and paints);

- glassy surfaces must be made roughness;

- to enhance contact with the mix, treat the surface with high absorptive capacity with the primer ТМ MASTER or ТМ іMASTER (4 hours before the start of work);

- bases with fungal lesions must be treated with the antifungal primer ТМ MASTER or ТМ іMASTER.

 

INSTRUCTIONS FOR USE

Perform the work at an air temperature of +50С to +250С. The temperature of the base must be in the same range.

Two days before the start of work, in the process of its performance, and for three days after the end maintain the temperature indoors not below +50Сand not above +250С.

Mechanical plastering must be held by a team of plasterers. Prepare the plaster machine according to the User's Guide. Add the dry mix into the hopper. Set the water flow to meet the requirements of technical documentation and specifications.

In the case of manual application add pure water to the dry mixture in an amount indicated in specifications, then mix it (use electric drills with screw socket). Leave stirred mix for 5 minutes, and then stir again. Apply the stirred mix ТМ  MASTER. CONTOURon the surface with a trowel or a float.

When arranging multilayer plaster coating, each subsequent layer must be applied after previous solidification. The applied layer must be evened before the beginning of the mix solidification.

Plaster sanding and application of paint and decorative coating materials must be made no earlier than 48 hours after applying the last layer of the mix.

NOTE TO A BUYER

- The base strength must be not less than the strength of the mix;

- Failure to follow the instructions for use mentioned on the package may adversely affect the aesthetic and performance properties;

- Products are not subject to mandatory certification;

- The mix is safe for human health in the production, transportation, storage, application and during the operation subject to following the requirements of this standard to production safety and health;

- Keep away from children;

- Date of manufacture, shelf life and batch number are mentioned on the package;

- Use only for the intended purpose.

- The manufacturer is not responsible for the use of the material for the purpose and under conditions not covered by this instruction.

- This instruction is a recommendation and does not substitute the professional training of the contractor.

Dry building mix ТМ MASTER CV.1.SHT2 DSTU B V.2.7-126: 2011

Ingredients

Cement-lime mix, modified with mineral fillers

Size of aggregate, maximum

0.8 mm

Time the closed mix is suitable for use

120 minutes

Strength of adhesion to base

0.5 MPa

Max compressive strength

5 MPa

Recommended amount of water for preparing the mix

0.2 L / 1 kg

Application temperature

+5ºС to +25ºС

Operation temperature

-40ºС to +70ºС

Consumption

1.35 kg / m2 / 1 mm

All of these recommendations are efficient at +200С and relative humidity of 60%.

SAFETY RULES

 

Dry building mixture contains cement, which causes alkaline reaction in hydration. When using the mix, use the personal protective equipment (respirator and rubber gloves). When working, protect the skin and eyes. In case of a mixture contact with eyes, rinse them immediately with plenty of water and seek medical advice.

 

Expiration date: 12 months from the date of manufacture mentioned on the package.

 

Must be disposed of in accordance the State Standard of Ukraine DSanPiN 2.2.7.029

 

Storage conditions: Store in the original intact packaging, on pallets, in dry premises at temperatures below +400С and humidity of 75%.

Warranty period: The manufacturer guarantees compliance of the quality with the requirements of this standard for the period specified on the package, provided the requirements of transport and storage are followed.