Standard

Standard

STANDARD
HIGH ADHESIVE MIX FOR FINISHIN FOR FACING MATERIALS

  • No slipping from vertical surfaces!
  • Easy to use
  • For indoor and outdoor use
  • High adhesion to surfaces with water absorption of 1% and above
  • Plastic
  • Freeze proof
  • Waterproof

Quality Certificate:
EN 12004:2007 + А1: 2012


Dry building mix  ТМ MASTER C.1.ЗК1 DSTU B V.2.7-126:2011
25 kg +/- 1%, 5 kg +/- 1%

 

Modified dry building mix ТМ MASTER. STANDARD designed for facing walls and floors with ceramic and porcelain tiles (with the water absorption of more than 1%) on concrete, brick, cement, sand, and cement and lime surfaces on solid non-deformed bases inside and outside the buildings.

 

SURFACE PREPARATION

Surface preparation must be done in accordance with the State Building Standard of Ukraine DBN V.2.6-22-2001. The base must be:

- clean (remove dirt, flows, dust, fungal lesions with a power tool or manually);

- strong (not lower than the coating strength);

- align uneven surfaces of 3 to 10 mm with the adhesive mixture ТМ MASTER. STANDART;

- in the presence of cracks, depressions or irregularities greater than 10 mm treat the base with primer ТМ MASTER or ТМ іMASTER, and then align with the plaster mix ТМ MASTER or ТМ іMASTER (24 hours before the start of work);

- the surface with high water absorption and air temperature above +300С require additional moisturizing;

- surfaces pretreated with primer ТМ MASTER or ТМ iMASTER do not require moistening.

 

INSTRUCTIONS FOR USE

Perform the work at an air temperature of +50С to +350С. The temperature of the base must be in the same range.

Two days before the start of plastering, in the process of its performance, and for three days after the end maintain the temperature indoors not below +50С and not above +350С.

Add pure water to the dry mixture in an amount indicated in specifications, then mix it (use electric drills with screw socket). Leave closed mix for 5 minutes, then stir again. The closed mix is suitable for use within 120 minutes (at recommended atmospheric conditions). At high temperatures, periodically stir the closed mix to avoid reducing its mobility.

Apply the closed mix ТМ MASTER. STANDARD on the surface with a trowel, float or leveling plate, then spread with a notched trowel. Trowel notches must match the size of the tiles as per the table.

Tile size, mm

Float notch size, mm

Mix average consumption, kg/m2

min 50x50

4

2.0

50x50 to 100x100

4

2.0

100х100 to 200х200

6

2.2

200х200 to 300х300

8

2.8

300х300 to 350х350

10

3.5

Apply the facing material on the applied mix and press with a force to the base. Do not apply tiles without joints. The joint between tiles must be at least 2 mm. Do not soak tiles in advance!

For exterior work, additionally apply the prepared mix TM MASTER. STANDARD with a thin layer (1-2 mm) directly on tiles.

Conduct grouting between tiles no earlier than 24 hours after tiling. We recommend using grout ТМ iMASTER.

In case of facing floors, displacement is possible not earlier than after 48 hours.

NOTE TO A BUYER

- The base strength must be not less than the strength of the mix;

- Failure to follow the instructions for use mentioned on the package may adversely affect the aesthetic and performance properties;

- Products are not subject to mandatory certification;

- The mix is safe for human health in the production, transportation, storage, application and during the operation subject to following the requirements of this standard to production safety and health;

- Keep away from children;

- Date of manufacture, shelf life and batch number are mentioned on the package;

- Use only for the intended purpose.

- The manufacturer is not responsible for the use of the material for the purpose and under conditions not covered by this instruction.

- This instruction is a recommendation and does not substitute the professional training of the contractor.

Dry building mix  ТМ MASTER C.1.ЗК1 DSTU B V.2.7-126:2011

Ingredients

Cement-sand mix, modified with polymeric additives

Size of aggregate, maximum

0.8 mm

Time the closed mix is suitable for use

120 minutes

Open time

10 - 15 minutes

Adjustment time

15 - 20 minutes

Strength of adhesion to base

0.8 MPa

Displacement of material from the vertical surface, max

0.1 mm

Recommended amount of water for preparing the mix

0.18-0.2 L / 1 kg

Application temperature

+50С to +350С

Operation temperature

-500С to +700С

Frost resistance, min

50 cycles

All of these recommendations are efficient at +200С and relative humidity of 60%.

SAFETY RULES

Dry building mixture contains cement, which causes alkaline reaction in hydration. When using the mix, use the personal protective equipment (respirator and rubber gloves). When working, protect the skin and eyes. In case of a mixture contact with eyes, rinse them immediately with plenty of water and seek medical advice.
 

Expiration date: 12 months from the date of manufacture mentioned on the package.

Must be disposed of in accordance the State Standard of Ukraine DSanPiN 2.2.7.029

Storage conditions: Store in the original intact packaging, on pallets, in dry premises at temperatures below 400С and humidity of 75%.

Warranty period: The manufacturer guarantees compliance of the quality with the requirements of this standard for the period specified on the package, provided the requirements of transport and storage are followed.