GYPSUM ADHESIVE MIX FOR BINDING GYPSUM PRODUCTS

  • For bonding plasterboards, gypsum composite panels and installation of gypsum partition boards
  • Suitable for facing with light materials
  • Suitable for mounting without screws and studs
  • Ideal for laying aerocrete blocks
  • Ideal for window jamb extensions
  • Resistant to slipping and hhighly plastic
  • Resistant to shock    
  • High adhesion                                                         
  • Vapor permeable
  • Fast setting 

Dry building mix  ТМ MASTER G.2.ЗК6 white DSTU B V.2.7-126:2011

Bar-code: 4820086382335

15 kg +/- 1%, 30 kg +/- 1%

 

Dry gypsum modified building mix for mounting ТМ MASTER. UNIFIX designed for bonding plasterboards and gypsum composite panels to concrete, bricks, aerocrete surfaces with irregularities; for laying gypsum blocks and arranging window jamb extensions inside buildings. Suitable for installation of decorative gypsum elements, curtain rods and more. For internal use.

 

SURFACE PREPARATION

Surface preparation must be done in accordance with the State Building Standard of Ukraine DBN V.2.6-22-2001. The base must be:

- clean (remove dirt, flows, dust, fungal lesions with a power tool or manually);

- strong (not lower than the coating strength);

- dry (moisture content less than 4%);

- if there are irregularities of more than 20 mm, align the base with the plaster mix ТМ MASTER;

- to enhance contact with the mix, treat the surface with the primer ТМ MASTER or ТМ іMASTER;

- to reduce water absorption, treat the surface with the primer paint ТМ MASTER. CONTACT (3 hours before the start of work);

 

INSTRUCTIONS FOR USE

Perform the work at air and surface base temperature of +100С to +300С, and the humidity no higher than 70%. The result will be efficient at +200С and relative humidity of 60%. In other conditions features may vary. Particular attention must be paid to the humidity in the room - the gypsum mix is used in dry environmental conditions. Two days before the start of work, in the process of its performance, and for three days after the end maintain the temperature and humidity indoors not above the specified ones.

Add pure water to the dry mixture in an amount indicated in specifications, then mix it (use electric drills with screw socket). Leave closed mix for 5 minutes, then stir again. The closed mix is suitable for use within 60 minutes (at recommended atmospheric conditions). Apply the closed mix ТМ MASTER. UNIFIX» on the board surface around the perimeter with minimal gap and at a distance of 35 cm in the middle of the board. Press the board with the applied mix firmly to the base by means of the leveling plate to and adjust with light strikes. Conduct grouting between tiles no earlier than 6 hours after installation. NOTE! Installation of plasterboards and gypsum composite panels must be carried out after the work that can cause deformation of boards.


NOTE TO A BUYER

- The base strength must be not less than the strength of the mix;

- Failure to follow the instructions for use mentioned on the package may adversely affect the aesthetic and performance properties;

- Products are not subject to mandatory certification;

- The mix is safe for human health in the production, transportation, storage, application and during the operation subject to following the requirements of this standard to production safety and health;

- Keep away from children;

- Date of manufacture, shelf life and batch number are mentioned on the package;

- Use only for the intended purpose.

- The manufacturer is not responsible for the use of the material for the purpose and under conditions not covered by this instruction.

- This instruction is a recommendation and does not substitute the professional training of the contractor.          

Dry building mix  ТМ MASTER G.2.ЗК6 white DSTU B V.2.7-126:2011

Ingredients

Mix of gypsum and lime, modified by polymeric additives

Size of aggregate, maximum

1.0 mm

Time the closed mix is suitable for use

60 minutes

Open time (depending on atmospheric conditions)

15 minutes

Strength of adhesion to base

0.8 MPa

Recommended amount of water for preparing the mix

0.35-0.40 L / 1 kg

Mix consumption depending on method of usage

1.1 kg / m2 / 1 mm

All of these recommendations are efficient at +200С and relative humidity of 60%.

SAFETY RULES

When using the mix, use the personal protective equipment (respirator and rubber gloves). When working, protect the skin and eyes. In case of a mixture contact with eyes, rinse them immediately with plenty of water and seek medical advice. 

Expiration date: 12 months from the date of manufacture mentioned on the package.

Must be disposed of in accordance the State Standard of Ukraine DSanPiN 2.2.7.029

Storage conditions: Store in the original intact packaging, on pallets, in dry premises at temperatures below 400С and humidity of 75%.

Warranty period: The manufacturer guarantees compliance of the quality with the requirements of this standard for the period specified on the package, provided the requirements of transport and storage are followed.